NovAseptic® valves have been specially designed for aseptic applications and comply with the most stringent regulations for cleanability and sterilizability. The aseptic process-oriented design is a key feature of all valves. Samplel valves are often the best option when branches need to be integrated into aseptic distribution systems for pure water and water for injections (WFI).
Material
Ethylen-Propylen-Dien-Monomer (EPDM)
Design Temperature Diaphragm
Short Term Use <1h continuously
  • NA 12 to NA 51: -30 to 140 ºC (-22 to 284 ºF)
  • NA 76: -30 to 128 ºC (-22 to 262 ˚F)

Design Pressure Diaphragm
-1 to 6 bar(g) (-14.5 to 87.0 psi(g))
Technical Datasheet and dimensions
open close
Brochure Novaseptic
open close
Diaphragms EPDM
Size Material Version Article Nr
3" (DN65 / DN80) EPDM until June 2022 N.NA76/22
2" (DN50) EPDM as of june 2022 N.NA51/22TR
1 1/2" (DN40) EPDM as of june 2022 N.NA38/22TR
1" (DN25) EPDM as of june 2022 N.NA25/22TR
3/4" (DN20) EPDM as of june 2022 N.NA18/22TR
1/2" (DN15) EPDM as of june 2022 N.NA12/22TR