Introduction

In the pharmaceutical, biotechnological, chemical, cosmetic, and food industries, pumps are at the heart of production processes. They ensure the transfer of sensitive, sterile, viscous, or particle-laden liquids, while meeting stringent safety and performance requirements. Yet, despite their critical role, the same issues frequently occur in many installations.
This article reviews the ten most common problems encountered with pumps, explains their impact on processes, and provides practical solutions to prevent them.

1. Compatibility of liquids with materials and seals

Pumps are in constant contact with fluids that can be corrosive, oxidizing, fatty, or chemically aggressive. When the pumped liquid is not compatible with the materials of construction (metals, seals, membranes, mechanical seals), various reactions can occur: swelling or cracking of elastomers, corrosion of stainless steel, or gradual dissolution of polymers. In pharmaceutical processes, this can lead to contamination due to particle release; in food production, to alterations in taste or color; and in chemical applications, to hazardous leaks for operators. Beyond the health and safety risks, material incompatibility significantly shortens the service life of the equipment and causes costly production downtime.


Solution: Select contact materials according to the chemical compatibility of the fluid (PTFE, EPDM, Viton®, stainless steel 316L, Hastelloy, PFA, etc.) and verify this compatibility already during the process design phase.

2. Solid particles in the fluid

Many processes require pumping liquids that contain solid particles — such as crystals in chemical applications, microbeads in cosmetics, plant fibers in the food industry, or cells in biotechnology. If the pump is not designed for this type of fluid, these particles can clog the passages, scratch internal surfaces, or block the rotors. Over time, this leads to reduced performance, premature wear, and even complete pump failure. In biopharmaceutical applications, the mechanical destruction of cells or aggregates can directly compromise the quality of the final product.


Solution: Use pumps specifically designed to handle particle-laden fluids (lobe pumps, diaphragm pumps, or peristaltic pumps), install safety filters upstream, and define the maximum acceptable particle size.

3. Fluid viscosity

When fluids are highly viscous — such as creams, syrups, gels, or food pastes — they require significantly more energy to be pumped. If the pump is not suitable for such conditions, it can lead to motor overheating, a drastic drop in flow rate, or even a complete shutdown. In chemical or cosmetic processes, this often results in incomplete mixing and non-compliant final products.


Solution: Use positive displacement pumps (lobe, screw, or reinforced peristaltic pumps) specifically designed for high-viscosity fluids, and adjust the motor power accordingly.

4. Cleaning and sterilization challenges (CIP/SIP)

In regulated industries, hygiene is essential. However, some pumps have dead zones, gaps, or complex geometries that make cleaning incomplete. This encourages residue buildup, biofilm formation, and increases the risk of cross-contamination. In pharmaceutical production, such issues can lead to FDA/EMA non-compliance and batch rejection. In food processing, they can even cause large-scale product recalls.


Solution: Use hygienic pumps certified by EHEDG or 3-A, with aseptic design, polished surfaces, and flush-mounted seals validated for CIP/SIP procedures.

5. Cavitation

Cavitation is a hydraulic phenomenon that occurs when the suction pressure is too low to keep the liquid in its fluid state. Vapor bubbles form and then implode inside the pumping chamber, creating powerful micro-explosions. This results in noise, vibration, and rapid erosion of metallic surfaces. In the short term, efficiency decreases; in the long term, impellers or suction areas can be severely damaged. In pharmaceutical or food installations, cavitation can also compromise sterility by creating microcracks and dead zones.


Solution: Check the available NPSH, minimize pressure losses upstream (larger pipes, fewer bends), maintain adequate liquid levels in tanks, or select a pump designed to resist cavitation.

6. Flow regulation

The flow rate of a pump depends on its rotation speed and the circuit conditions. When it is not properly controlled, the flow can be too high (energy overuse, fluid shear) or too low (poor filling, efficiency loss). In sensitive processes like injectable drug production, unstable flow leads to inaccurate dosing and loss of compliance. In food production, it can affect product texture, causing non-homogeneous mixtures or excessive aeration.


Solution: Use frequency converters (VFDs), integrate flow sensors, and implement automatic control loops to adjust pumping in real time.

7. Insufficient self-priming capability

Some pumps cannot re-prime themselves after shutdown or line draining, leaving the pump dry and unable to restart flow. This leads to frequent blockages, material losses, and production delays. In pharmaceutical contexts, this can halt entire campaigns and waste valuable production time.


Solution: Choose self-priming pumps (peristaltic, diaphragm, side-channel types) or install an external priming system.

8. Risk of cross-contamination

When the same pump is used for multiple products or production campaigns, residual fluid may remain trapped in the pump chamber or internal passages. Even trace amounts can contaminate the next batch. In pharmaceuticals, this constitutes a major non-conformity and can invalidate a full production run. In cosmetics, it can alter purity, fragrance, or product stability.


Solution: Use single-use pumps when appropriate or apply validated, rigorous cleaning and sterilization procedures.

9. Excessive noise and vibration

A poorly sized, unbalanced, or misaligned pump can generate significant noise and vibration. These stresses accelerate mechanical wear, shorten the equipment’s lifespan, and increase maintenance costs. In sensitive environments like cleanrooms, vibrations may also interfere with precision instruments.


Solution: Properly size the pump, ensure correct shaft alignment, use anti-vibration mounts, and perform dynamic balancing when necessary.

10. High energy consumption

Pumps account for a substantial share of a plant’s energy consumption. A poorly selected or poorly maintained pump quickly loses efficiency and consumes far more electricity than expected. In continuous operation, this can represent tens of thousands of euros annually and undermine sustainability goals.


Solution: Select high-efficiency pumps, use variable-speed drives to optimize operation, and perform regular preventive maintenance.

Conclusion

Most pump-related issues do not originate from the equipment itself, but from improper design, poor material selection, or inadequate maintenance. In industries where hygiene, safety, and reliability are critical, these errors can have severe consequences: product loss, contamination, recalls, and excessive energy costs.


Aseptconn supports its customers in selecting, validating, and optimizing their pumping solutions to ensure performance, safety, and regulatory compliance — even in the most demanding environments.